Overview
Introducing the MultiFiber™ Pro Optical Power Meter and Fiber Test Kits. MultiFiber Pro is the only fiber tester that can test MPO fiber trunks without the use of a fan-out cords, it eliminates the complexity of polarity issues, and it makes cassettes easier to test in the field. Whether it is using 10 Gbps preterminated fiber trunks or planning for next-generation 40/100 Gbps performance, data centers are standardizing on an MPO connector solution. Typical data center fiber installation means time-consuming, manual and imprecise MPO validation. MultiFiber Pro is 90 percent faster than the single fiber testing method because it measures power loss and validates polarity on 12 fibers in a single connector— reducing test time from weeks to days.
Features
Order Information
Model Number/Name |
Description |
MFTK1200 |
MultiFiber Pro Testing Base Kit includes MultiFiber Pro Power Meter, 850 Light Source, Test Cords, MPO adapters, and carrying case |
MFTK1400 |
MultiFiber Pro Testing and Inspection Kit includes MFTK1200, FT600 FiberInspector Pro with NF370 MPO Tip |
Picture Detail
Specifications
General | |
Operating temperature | -10ºC to +50ºC |
Storage temperature | -20ºC to +50ºC<10ºC |
Operating humidity | 95% (10ºC to +35ºC) non-condensing |
75% (35ºC to +45ºC) non-condensing | |
Uncontrolled <10ºC | |
Operating altitude | 4,000 m |
Storage altitude | 12,000 m |
Vibration | Random 2 G, 5 Hz to 500 Hz |
Optical Power Meter ( apply at 23ºC (73ºF), unless otherwise noted.) | |
Detector type | InGaAs |
Calibrated wavelengths | 850 nm, 1300 nm, 1310 nm, 1550 nm |
Measurement range | 0 dBm to -50 dBm |
Power measurement linearity | ±0.1 dB1 |
Power measurement uncertainty | ±0.35 dB |
Power measurement repeatability | < 0.10 dB |
Display resolution, dB or dBm | 0.01 dB |
Power display units | dBm, mW, μW |
User-selectable limit for loss | 0.05 dB to 50.0 dB, in increments of 0.05 dB up to 10.0 dB and 0.1 dB up to 50.0 dB |
Auto wavelength detection | Yes |
Polarity detection | Detects A, B, C, and Corning Plug & Play™ Universal Systems polarities |
2 kHz detection | Yes |
Record storage | 3000 records, one fiber per record (250 12-fiber cables) |
External interface | USB 2.0, full speed |
Optical connector |
MPO interface for 12-fiber, unpinned plugs. Compatible with 50 μm and singlemode fibers. Connector has a self-closing, protective cover. |
Power requirement | 2 AA alkaline batteries |
Battery life2 | >30 hours (typical) |
Automatic power-off | 10, 20, 30, or 60 minutes (can be disabled by the user) |
Low battery warning | Low battery icon blinks |
Size | 5.7 in x 3.2 in x 1.5 in (14.5 cm x 8.0 cm x 3.9 cm) |
Weight | 10.9 oz (309 g) |
850nm Source ( apply at 23ºC (73ºF), unless otherwise noted) | |
Emitter type | LED: 850 nm |
Wavelength | 850 nm: ±30 nm |
Spectral width (FWHM) | 850 nm: ±50 nm (typical) |
Output power | 850 nm: ≥ 24 dBm Max difference between channels +/-1dB |
Power output stability3 | ≤ ±0.1 dB over 8 hours |
Encircled flux | Meets ANSI/TIA-526-14B, ISO/IEC 14763-3, and IEC 61280-4-1 for 50/125 μm at the source's optical connector. |
Optical connector | MPO interface for 12-fiber, unpinned plugs. Compatible with 62.5 μm and 50 μm. |
Modes | 2 kHz modulated, auto wavelength |
Power requirement | 2 AA alkaline batteries |
Battery life4 | >30 hours (typical) |
Automatic power-off | 10, 20, 30, or 60 minutes (can be disabled by the user) |
Low battery warning | Low battery icon blinks |
Size | 5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1 cm) |
Weight | 10.9 oz (309 g) |
1. For 850 nm, 0 dBm to -50 dBm. For 1300, 1310, 1550 nm, -5 to -50 dBm | |
2. Measured power levels ≤0 dBm. Backlight on. Battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries |
|
3. 23°C ±2°C, after 10 minutes of warm-up time | |
4. Auto wavelength,SCAN ALL, and backlight on. Battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries |