Fiberinthebox

Payment & Guarantee Support


Fluke Networks OFP-100-M OptiFiber Pro Multimode OTDR kit

SKU#:FITB53723NJT
Model#: OFP-100-M
Price: US$ 18,525.00
Sold: 683
Availability: In Stock
Qty:
fiberinthebox-bbb-a-plus-certification fiberinthebox-product-certification
Overview
OptiFiber® Pro is the industry's first OTDR built from the ground up to meet the challenges of enterprise fiber infrastructures. This troubleshooting and ce ification tool combines uncomplicated power, unparalleled efficiency and the exact functions needed for troubleshooting campus, data center and storage fiber networks.
The OptiFiber® Pro OTDR elevates fiber testing with the industry's only sma phone interface that turns a technician into a fiber expe . The DataCenter OTDR configuration eliminates unce ainty and errors that occur when testing data center fiber. Its ultra-sho dead zones enable testing of fiber patchcords in vi ualized data centers. These capabilities, plus the fastest-in-the-industry trace times, make the OptiFiber Pro OTDR a must-have tool.
Features
Sma phone, "gesture-based" interface that allows anyone to perform expe fiber testing with maximum efficiency Fastest trace time at 2 seconds per wavelength to accelerate fiber ce ification and troubleshooting Ultra-sho dead zones to analyze datacenter fibers with sho fiber patch cables and dense connectors "DataCenter OTDR" configuration to effectively test datacenter fiber with minimal set-up and trace time Graphical EventMap view greatly simplifies the interpretation of OTDR trace results Project management capability enables efficient job and user assignments and tracks project progress with pass/fail results Enhanced productivity with the fastest trace times, one-button set ups and integrated repo ing Maximized operator efficiency with task-focused, simplified usability Increased reliability of all high-bandwidth networks
Order Information

Model Number/Name

Description

OFP-100-M

OptiFiber Pro Multimode OTDR kit. This kit includes the OptiFiber Pro with MM OTDR module, carrying strap, AC adapter/charger, USB interface cable – standard A to micro B, user guide CD, LinkWare software CD, Getting Sta ed Guide, statement of calibration, registration card, factory-based warranty and carrying case.

OFP-100-MI

OptiFiber Pro Multimode OTDR kit with inspection kit. This kit includes the OptiFiber Pro with MM OTDR module, 2 SC/LC multimode launch cables—50 µm, 1 SC/SC multimode launch cable—50 µm, USB fiber inspection video probe with 4 tips, 2 launch fiber tool packs, OptiFiber Pro carrying and hand strap, AC adapter/charger, USB interface cable – standard A to micro B, 1 1.25 mm IBC OneClick cleaner, 1 2.5 mm IBC OneClick cleaner, user guide CD, LinkWare software CD, Getting Sta ed Guide, statement of calibration, registration card, factory-based warranty and carrying case.

OFP-100-S

OptiFiber Pro Singlemode OTDR kit. This kit includes the OptiFiber Pro with SM OTDR module, carrying strap, AC adapter/charger, USB interface cable – standard A to micro B, user guide CD, LinkWare software CD, Getting Sta ed Guide, statement of calibration, registration card, factory-based warranty and carrying case.

OFP-100-SI/CH

OptiFiber Pro Singlemode OTDR kit with inspection kit. This kit includes the SC/SC singlemode launch cables—9 µm, USB fiber inspection video probe with 4 tips, 2 launch fiber tool packs, OptiFiber Pro carrying and hand strap, AC adapter/charger, USB interface cable – standard A to micro B, 1 1.25 mm IBC OneClick cleaner, 1 2.5 mm IBC OneClick cleaner, user guide CD, LinkWare software CD, Getting Sta ed Guide, statement of calibration, registration card, factory-based warranty and carrying case.

OFP-100-Q/CH

OptiFiber Pro Quad OTDR kit. This kit includes the OptiFiber Pro with Quad OTDR module, 2 SC/LC multimode launch cables—50 µm, 2 SC/LC single timode launch cables—9 µm, 1 SC/SC multimode launch cable—50 µm, 1 SC/SC single timode launch cable—9 µm, USB fiber inspection video probe with 4 tips, 2 launch fiber tool packs, OptiFiber Pro carrying and hand strap, AC adapter/charger, USB interface cable – standard A to micro B, 1 1.25 mm IBC OneClick cleaner, 1 2.5 mm IBC OneClick cleaner, user guide CD, LinkWare software CD, Getting Sta ed Guide, statement of calibration, registration card, factory-based warranty and carrying case.

Picture Detail
Key OTDR specifications
  Multimode module Singlemode module Quad module
Wavelengths 850 nm +/- 10 nm 1310 nm +/- 25 nm 850 nm +/- 10 nm
1300 nm +35/-15 nm
1310 nm +/- 25 nm
1300 nm +35/-15 nm 1550 nm +/- 30 nm 1550 nm +/- 30 nm
Compatible 
fiber types
50/125 µm Singlemode 50/125 µm
62.5/125 µm
62.5/125 µm Singlemode
Event dead 
zone 1
850 nm: 0.5 m typical 1310 nm: 0.6 m typical 850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1300 nm: 0.7 m typical 1550 nm: 0.6 m typical 1550 nm: 0.6 m typical
Attenuation 
dead zone 2
850 nm: 2.5 m typical 1310 nm: 3.6 m typical 850 nm: 2.5 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1300 nm: 4.5 m typical 1550 nm: 3.7 m typical 1550 nm: 3.7 m typical
Dynamic range 
3, 5, 6
850 nm: 28 dB typical 1310 nm: 32 dB typical 850 nm: 28 dB typical
1300 nm: 30 dB typical
1310 nm: 32 dB typical
1300 nm: 30 dB typical 1550 nm: 30 dB typical 1550 nm: 30 dB typical
Max distance 
range setting
40 km 130 km MM: 40 km
SM: 130 km
Distance 
measurement 
range 4, 5, 
7, 8, 9, 10
850 nm: 9 km 1310 nm: 80 km 850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1300 nm: 35 km 1550 nm: 130 km 1550 nm: 130 km
Reflectance 
range 4, 5
850 nm: -14 dB to -57 dB 
(typical)
1310 nm: -14 dB to -65 dB 
(typical)
850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65dB (typical)
1300 nm: -14 dB to -62 dB (typical) 1550 nm: -14 dB to -65 dB (typical) 1550 nm: -14 dB to -65 dB (typical)
Sample resolution 3 cm to 400 cm 3 cm to 400 cm 3 cm to 400 cm
Pulse widths 
(nominal)
850 nm: 3, 5, 20, 40, 200 ns 1310/1550 nm: 3, 10, 30, 100, 
300, 1000, 3000, 10000, 20000 ns
850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns 1310/1550 nm: 3, 10, 30, 100, 300, 
1000, 3000, 10000, 20000 ns
Test time 
(per wavelength)
Auto setting: 5 sec (typical) Auto setting: 10 sec (typical) Auto setting:
MM – 5 sec (typical)
SM – 10 sec (typical)
Quick test setting: Quick test setting: Quick test setting:
MM – 2 sec (typical)
2 sec (typical) 5 sec (typical) SM – 5 sec (typical)
Best resolution setting: Best resolution setting: Best resolution setting:
MM – 2 to 180 sec M
2 to 180 sec 5 to 180 sec SM – 5 to 180 sec
FaultMap setting: FaultMap setting: FaultMap setting:
MM - 2 sec (typical), MM - 180 sec (max)
2 sec (typical), 180 sec (max) 10 sec (typical), 180 sec (max) SM - 10 sec (typical), SM - 180 sec (max)
DataCenter OTDR setting: DataCenter OTDR setting: DataCenter OTDR setting:
MM – 1 sec (typical at 850 nm) 
MM – 7 sec (max)
1 sec (typical at 850 nm), 7 sec (max) 20 sec (typical), 40 sec (max) SM – 20 sec (typical) SM – 40 sec (max)
Manual setting: Manual setting: Manual setting:
3, 5, 10, 20, 40, 60, 90, 120, 180 sec 3, 5, 10, 20, 40, 60, 90, 120, 180 sec -3, 5, 10, 20, 40, 60, 90, 120, 180 sec 
SM - 3, 5, 10, 20, 40, 60, 90, 120, 180 sec
 
1. Measured at 1.5 dB below non-saturating reflection peak with the shortest pulse width. Reflection peak < -40 dB for multimode and 
< - 50 dB for singlemode.
2. Measured at +/- 0.5 dB deviation from backscatter with the shortest pulse width. Reflection peak < -40 dB for multimode and 
<- 50 dB for singlemode.
3. For typical backscatter coefficient for OM1 fiber: 850: -65 dB, 1300: -72 dB.
4. Typical backscatter and attenuation coefficients for OM2-OM4 fiber: 850 nm: -68 dB; 2.3 dB/km: 1300 nm: -76 dB; 0.6 dB/km.
5. Typical backscatter and attenuation coefficients for OS1-OS2 fiber: 1310nm : -79 dB; 0.32 dB/km; 1550 nm: -82 dB; 0.19 dB/km.
6. SNR=1 method, 3 minute averaging, widest pulse width.
7. 850 = 9 km typical to find the end or 7 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
8. 1300 = 35 km typical to find the end or 30 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
9. 1310 = 80 km typical to find the end or 60km typical to find a 0.1 dB event (with a maximum of 20 dB attenuation prior to the event).
10. 1550 = 130 km typical to find the end or 90 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
11. Does not include index of refraction error and does not include automatic event location error.
12. dB variation per 1 dB step.
13.Applies along the trace backscatter within the distance range in which the OTDR can find a 0.1 dB event.