Overview
Use FiberViewer microscopes to ensure fiber terminations are smooth and clean. Avoid the #1cause of cause of fiber link failure: di y end-faces.
Di , dust and other contaminants are the enemy of high-speed data transmission over optical fiber. Today's network applications require more bandwidth, making loss budgets tighter than ever. It is critical that all optical connections are clean and free of contaminants to ensure application success. With universal adapters, end-faces can be inspected when using many different connector types, including LC connectors.
Di , dust and other contaminants are the enemy of high-speed data transmission over optical fiber. Today's network applications require more bandwidth, making loss budgets tighter than ever. It is critical that all optical connections are clean and free of contaminants to ensure application success. With universal adapters, end-faces can be inspected when using many different connector types, including LC connectors.
Features
Rugged, po able, ergonomic tool Easy, manual focus of precision optics Factory-tested filters to protect eyes from harmful light exposure Universal adapters allow for inspection of end-faces on many different connector types Available in 200x or 400x magnification
Order Information
Model Number/Name |
Description |
FT120 | Fiber Viewer - 200X magnification with 2.5mm Universal Adapter |
FT140 | Fiber Viewer - 400X magnification with 2.5mm Universal Adapter |
Specifications
General | |||
Magnification | FT120: 200X; FT140: 400X | ||
Fiber adapter | 2.5 mm universal ferrule adapter for multimode or singlemode fibers | ||
Power supply | Three 1.5 V AAA batteries (NEDA 24A or IEC LR03). 35 hours typical use with alkaline batteries. | ||
Light source | White LED (100,000 hour life) | ||
Optical Laser Safety Filter | |||
Wavelength | |||
850 nm | 1310 nm | 1550 nm | |
Optical Density | 2.05 | 5.1 | 4.3 |
Attenuation | 20.5 dB | 51.0 dB | 43.0 dB |
Peak Power Rating* | 49 mW | 1000 W | 190 W |