Description
The FS-1CS Datacom/2M Transmission Analyzer is a kind of instrument that especially useful in the installation, field operation and maintenance of digital transmission systems. It is with LCD large-screen display and multi-task operation can be worked at one time, which is really a good choice for the technicists in the telecommunication access networks, transmission networks and the sta -up, check and maintenance of optical communications systems.
Features
LCD large-screen display, 320*240 lattice, backlight, LED indicatorHand held, auto configuration
Multi-task operation at one time
Store 20 test results and 9 test configurations, with power-off memories
PC operation, store, analysis, print
Programmable timer
Alarm and histogram analysis
Software updating
Major Functions
For 2Mbit/s:Service-interrupted error testing
Online error testing
Framed and unframed signals generation and reception
2Mbit/s unframed error performance testing
2Mbit/s framed N×64kbit/s channel error testing
Bit error, coding error, frame error, CRC error and E bit error testing
Signal loss alarm, AIS alarm, framed remote alarm, multi-framed remote alarm, out-of-frame, and pattern loss alarm
Frequency offset testing
Voice channel signal level and frequency testing
Pattern slip testing
Straightforward signaling
Audio frequency testing
Sound monitoring
Signal state display. Voice channel content display. Voice channel busy indication
Alarm and error histogram analysis
Time slot content analysis, drop and inse signal on each time slot
Framed content analysis
G. 821/G. 826/M. 2100 error analysis
Multi error and alarm inse ing
Three input modes (terminating, bridging and monitoring)
Two clock options (internal and picking-up)
For Datacom:
V.24/RS232/V.28, V.35, V.36, X.21, RS-449, RS-485, RS422, EIA-530, EIA datacom testing
SYNCH and ASYNCH testing
DTE and DCE emulation
Bit code testing
Pattern slip testing
Signal loss alarm
Line signal level and frequency testing
Loop delay testing
Automatic protection switching time testing(APS)
G.821, M2100 service interrupt error testing
For Co-directional 64Kbit/s:
Service interrupt error testing
Bit code testing
Pattern slip testing
Signal loss, AIS alarm
Line signal frequency testing
Loop delay testing
Automatic protection switching time testing(APS)
G.821, M.2100 error testing
Standard Package
FS-1CS Transmission Analyzer 1setUser’s manual 1pc
Software disc 1pc
75Ω Coaxial testing line 1pc
BNC-L9 Testing line or 120Ω testing line CESHIYI 2pc
RS232 serial line 1pc
Special testing cable of data communication Ⅰ(V.24, RS-485, EIA-530, EIA-530A) 1pc
Special testing cable of data communicationⅡ(RS-449, V .36) 1pc
Special testing cable of data communication Ⅲ (X .21) 1pc
Special testing cable of data communication Ⅳ (V .35) 1pc
G.703 CO special testing cable (64Kb/s coaxial interface) 1pc
Power adapter 1pc
Data self-loop head 1pc
Switch cable 1pc
Handy-case 1pc
The 2M Error rate tester is designed for 2M bit error rate test, applicable to telecommunication access networks, transmission networks and the sta -up, check and maintenance of optical communications systems. If you are interested in this FS-1CS Datacom/2M Transmission Analyzer, welcome to contact us, we also provide one year warranty for it.
Specifications
Technical Index
2Mbit/s Technical Index(1) Signal input rate: 2048kbit/s, 50ppm (G.703 requirement±100ppm)
(2) Signal code: HDB3, AMI.
(3) Input jitter tolerance: Up to the requirement of Figure 10.1.
Fig.10.1 Input Jitter Tolerance
(4) Input balance response: attenuation complies with the law of square root of frequency, and is within the range of 0 ~ 6dB at 1024 kHz.
(5) Input Impedance
(5.1) Unbalance terminating: 75Ω
Balance terminating: 120Ω
Reflection loss >18dB within 50Hz~3100kHz
(5.2) Unbalance bridging: >750Ω
Balance bridging: >1200Ω
(5.3) Unbalance monitoring: 75Ω, 26dB gain
Balance monitoring: 120Ω, 26dB gain
Reflection loss >18dB within 50Hz~3100kHz
(6) Signal structure
(6.1) Unframed structure
(6.2) Framed structure: PCM30, PCM31, PCM30CRC, PCM31CRC
Framed structure complies with the requirement of G. 704
(7) Testing pattern: 26-1, 29-1, 211-1, 215-1, 220-1, 223-1, and artificial code
(8) Impedance of output interface:
(8.1) Unbalance 75Ω, up to G. 703
(8.2) Balance 120Ω, up to G. 703
(9) External clock input
(9.1) Signal form: HDB3, NRZ
(9.2) Balance terminating resistance: 120Ω
Unbalance terminating resistance: 75Ω
Balance bridging resistance: >1200Ω
Unbalance bridging resistance: >750Ω
(10) Error code insertion: None, single, or ratio 10-1~10-7.
Co-directional64k Technical Index
(1) Signal input rate: 64kbit/s ± 50ppm(G.703 requirement±100ppm)
(2) Input impedance: Balance 120Ω, up to G.703
(3) Input jitter tolerance: Up to G.823.
(4) Impedance of output interface: Balance 120Ω, up to G.703
(5) Testing pattern: 26-1, 29-1, 211-1, 215-1, 220-1, 223-1, and artificial code
Datacom Index
(1) Data interface type: V.24, V.35, V.36, X.21, RS-449, RS-485, EIA-530 and EIA.
(2) Generator
(2.1) SYNCH mode
Clock source: Internal or external clock
Phase relation between clock and data: co-direction or reverse direction.
Rate: 1.2, 2.4, 4.8, 9.6, 14.4, 19.2, 38.4, 48, 56(kbps), N×64kbps (N=1~32)
Error: ±15ppm (ppm: parts per million)
(2.2) ASYNCH mode
Rate: 50,75,110,150,200,300,600,1200,2400,3600,4800,7200,9600; 14.4k,19.2k,38.4k,57.6k(bps)
Data structure: Word length: 5, 6, 7, 8(bits) Stop bit: 1, 2(bits)
Odd-even check: odd, even, 1, 0, none
(2.3) Error code insertion: None, single, or ratio 10-1~10-7.
(3) Receiver
(3.1) SYNCH mode
Clock source: Internal or external clock
Phase relation between receive clock and receive data: Equi direction or reverse direction.
Clock Rate: 2048kbps at a maximum
(3.2) ASYNCH mode
The rate and data are the same as those of the generator.
(4) Testing pattern: 26-1, 29-1, 211-1, 215-1, 220-1, 223-1, and artificial code
Other Parameters
Power supply
(1) Special power adapter
Input: AC220V 50Hz
Output: DC 9V 1.2A
(2) Internal rechargeable battery
4000mAh, 6V nickel-hydrogen rechargeable battery
Working time: 8 hours
Charging: 8 hours at power-off state, and 12 hours at power-on state
Dimension and weight
L×W×H: 200×162×48mm
Weight: 950g
Ambient parameters
Operation temperature: -10~50℃
Storage Temperature: -30~+70℃
Humidity: 5%~90%, non-condensing